A process run card encoded with bar-code information and providing controllers with scanners which can scan the bar-code information and configure the controller accordingly is disclosed. Such a system advantageously provides a semiconductor manufacturing system controller which minimizes or reduces the problems associated with having to reprogram controllers for various lots. ♦ PE – Protective Earth uses circuit protective conductors sized for short circuits where the voltage will not rise in excess of 50 Volts. This connection is normally used to ground the inverter. ♦ - Is the ground connection where the reference voltage can be the same as the Earth voltage. This connection is normally used to ground the motor.

  1. Blue Earth Micro 440 User's Manual 2016
  2. Blue Earth Micro 440 User's Manual Pdf
  3. Blue Earth Micro 440 User's Manual Instructions
  4. Blue Earth Micro 440 User's Manual Software
  5. Blue Earth Micro 440 User's Manual 2017
  6. Blue Earth Micro 440 User's Manual Free
  7. Blue Earth Micro 440 User's Manual Online
Advertising

Issue 10/06

7 Displays and messages

MICROMASTER 440
Operating Instructions (Compact)

77

7.2

Fault messages and Alarm messages

Fault Significance

Alarm Significance

F0001 Overcurrent

A0501 Current

Limit

F0002 Overvoltage

A0502 Overvoltage

limit

F0003 Undervoltage

A0503 Undervoltage

Limit

F0004 Inverter

Overtemperature

A0504 Inverter

Overtemperature

F0005 Inverter

I

2

t

A0505

Inverter

I

2

t

F0011

Motor Overtemperature I

2

t

A0506

Inverter

Duty

Cycle

F0012

Inverter temp. signal lost

A0511

Motor Overtemperature I

2

t

F0015

Motor temperature signal lost

A0520

Rectifier Overtemperature

F0020

Mains Phase Missing

A0521

Ambient Overtemperature

F0021

Blue

Earth fault

A0522

I2C read out timeout

F0022

HW monitoring active

A0523

Output fault

F0023

Output fault

A0535

Braking Resistor Hot

F0024

Rectifier Over Temperature

A0541

Motor Data Identification Active

F0030

Fan has failed

A0542

Speed Control Optimization Active

F0035

Auto restart after n

A0590

Encoder feedback loss warning

F0040

Automatic Calibration Failure

A0600

RTOS Overrun Warning

F0041

Motor Data Identification Failure

A0700 - CB warning 1

F0042

Speed Control Optimization Failure

...

...

F0051

Parameter EEPROM Fault

A0709

CB warning 9

Blue Earth Micro 440 User's Manual 2016

F0052

Power stack Fault

A0710

CB communication error

Blue Earth Micro 440 User's Manual Pdf

F0053

IO EEPROM Fault

A0711

CB configuration error

F0054

Blue Earth Micro 440 User's Manual Instructions

Wrong IO Board

A0910

Blue Earth Micro 440 User's Manual Software

Vdc-max controller de-activated

F0060

Asic Timeout

A0911

Vdc-max controller active

F0070

CB setpoint fault

A0912

Vdc-min controller active

F0071

USS (BOP link) setpoint fault

A0920

ADC parameters not set properly

F0072

USS (COM link) setpoint fault

A0921

DAC parameters not set properly

F0080

ADC lost input signal

A0922

No load applied to inverter

F0085

Blue Earth Micro 440 User's Manual 2017

External Fault

A0923

Both JOG Left and Right are requested

Blue Earth Micro 440 User's Manual Free

F0090

Encoder feedback loss

A0952

Blue Earth Micro 440 User's Manual Online

Belt Failure Detected

F0101

Stack Overflow

A0936

PID Autotuning Active

F0221

PID Feedback below min. value

F0222

PID Feedback above max. value

F0450

BIST Tests Failure
(Service mode only)

F0452

Belt Failure Detected