Bradford White Water Heater User Manual

Bradford-White Corp Water Heater 238-16152-00F. Bradford-White Corp INSTALLATION & OPERATING INSTRUCTION MANUAL COMMERCIAL ELECTRIC WATER HEATER. Recommend this water heater be installed and serviced by a plumbing professional. GAS-FIRED WATER HEATER INSTALLATION & OPERATION INSTRUCTION MANUAL For Flammable Vapor Ignition Resistant System Equipped Water Heater WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing.

'Highest in Subcontractor Satisfaction among Water Heater/Boiler Manufacturers'

Residential Ultra Low NOx Series

Energy Saver Gas Water Heater

The FVIR Eco-Defender Safety System® Models Feature:

Photo is of

U1-5036FRN

Identical Dimensions

Same diameter, height and connections as standard units

for ease of installation.

Defender Combustion Chamber—Incorporates the Advanced ScreenLok® Technology Flame Arrestor and large split-door design to prevent ignition of flammable vapors outside the water heater.

Ultra Low NOx Burner with Primary and Secondary Air Distribution Devices—Ensures proper air to gas ratio for reduction of NOx generated by the combustion process.

Digital Thermal Sensor and Resettable Thermal Switch—Coordinates with self diagnostic control to prevent water heater operation as needed.

Millivolt Powered Control with Built-in Piezo Igniter—Easy and quick lighting of the pilot burner by push button.

Pedestal Base—Rugged and durable base allows easy transport and positioning, while providing corrosion resistant contact with floor.

Maintenance Free—No regular cleaning of air inlet openings or flame arrestor is required under normal conditions.

Sight Window—Offers a view into the combustion chamber to observe the operation of the pilot and burner.

No Electricity Required.

Factory Installed Hydrojet® Total Performance System—Cold water inlet sediment reducing device helps prevent sediment build up in tank. Increases first hour delivery of hot water while minimizing temperature build up in tank.

Vitraglas® Lining—Bradford White water heater tanks are protected from the corrosive effects of hot water by an exclusive ceramic porcelain-like coating.

Self Diagnostic Honeywell Gas Control—Integrated, immersion gas control learns and monitors the combustion chamber's temperature profile and prevents water heater operation during upset conditions. Also equipped with an LED display to aid in start-up and diagnostics.

Side Connections—3/4' NPT tappings allow an easy connection for space heating applications (U1-XR-403S model only).

1' Non-CFC Foam Insulation—Surrounds the tank surface, saving energy by retarding loss of heat.

Water Connections—3⁄4' NPT factory installed true dielectric fittings extend water heater life and eases installation.

Factory Installed Heat Traps—Design incorporates a flexible disk that reduces heat loss in piping and eliminates the potential for noise generation.

Protective Magnesium Anode Rod—Provides added protection against corrosion for long trouble-free service.

3x4 “Snap Lock” Draft Diverter—Allows either 3' or 4' vent connections with inputs of 40,000 BTU/Hr. or less. Over 40,000 BTU/Hr. has the 4' “Snap Lock” Draft Diverter.

Flue Baffle—Maximizes the amount of heat absorbed by the tank and reduces heat loss during standby periods.

Steel Tank—Heavy gauge steel automatically formed, rolled and welded.

T&P Relief Valve—Included.

Brass Drain Valve.

Bradford white water heater troubleshooting

Meets SCAQMD Rule 1121 (10ng/J NOx limit).

Design Certified by CSA International (formerly AGA and CGA).

6 or 10-Year Limited Tank Warranties / 6-Year Limited Warranty on Component Parts.

For more information on warranty, please visit www.bradfordwhite.com

For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the warranty included with the heater.

Bradford White received the highest numerical score among water heater/boiler manufacturers in the proprietary J.D. Power and Associates/ McGraw-Hill Construction 2006 HVAC and Water Heater/Boiler Subcontractor Satisfaction StudySM. Study based on 882 responses measuring 3 water heater/boiler manufacturers and measures opinions of subcontractors. Proprietary study results are based on experiences and perceptions of subcontractors surveyed in May through July 2006. Your experiences may vary. Visit jdpower.com

MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 7,063,133 B2; 5,954,492; 5,761,379; 5,943,984; 5,081,696; 5,988,117; 6,142,216; 5,199,385; 5,574,822; 5,372,185; 5,485,879; 5,277,171; (B1)5,341,770; 5,660,165; 5,596,952; 5,682,666; 4,904,428; 5,023,031; 5,000,893; 4,669,448; 4,829,983; 4,808,356; 5,115,767; 5,092,519; 5,052,346; 4,416,222; 4,628,184; 4,861,968; 4,672,919; Re. 34,534. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 1,272,914; 1,280,043; 1,289,832; 2,045,862; 2,112,515; 2,108,186; 2,107,012; 2,092,105..

Defender Safety System®, ScreenLok®, Vitraglas® and Hydrojet® are registered trademarks of Bradford White® Corporation.

112-B-1007-A

Residential Atmospheric Vent Gas Water Heater

Bradford White Water Heater Installation …

Ultra Low NOx Energy Saver Models

Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed

NATURAL GAS

Recovery efficiency ranging up to 78%

Model

Capacity

Recovery at

A

B

C

D

E

F

G

H

K

Approx.

90°F Rise*

Floor to

Jacket

Vent

Floor to

Floor to

Floor to

Floor to

Floor to

Depth

Shipping

Number

Flue

Dia.

Size

T&P

Gas

Space

Space

Water

Weight

Nat.

Nat.

Nat.

U.S.

Imp.

Conn.

Conn.

Conn.

Heating

Heating

Conn.

BTU/Hr.

U.S.

Imp.

Return

Outlet

Gal.

Gal.

Input

GPH

GPH

in.

in.

in.

in.

in.

in.

in.

in.

in.

lbs.

U1-30S6FRN

30

25

30,000

31

26

483/8

18

3x4

383/4

115/8

-

-

463/4

221/4

110

U1-30T6FRN•

30

25

32,000

33

28

591/8

16

3x4

493/4 / 563/8

115/8

-

-

571/2

201/4

113

U1-403S6FRN•

40

33

40,000

42

34

50

20

3x4

41 / 471/4

115/8

-

-

481/2

241/4

137

U1-40T6FRN•

40

33

40,000

42

34

593/8

18

3x4

50 / 565/8

115/8

-

-

573/4

221/4

130

U1-404T6FRN•

40

33

50,000

53

44

603/4

18

4

511/2 / 58

115/8

-

-

581/2

221/4

137

U1-5036FRN•

50

42

40,000

42

34

595/8

20

3x4

50 / 567/8

115/8

-

-

58

241/4

154

U1-50L6FRN

48

40

40,000

42

34

493/4

22

3x4

401/2

115/8

-

-

481/4

261/4

163

U1-504S6FRN•

50

42

50,000

53

44

581/2

20

4

50 / 553/4

115/8

-

-

57

241/4

160

U1-XR-403S6FRN

40

33

40,000

43

36

50

20

3x4

41

13

131/2

41

481/2

241/4

137

Model

Capacity

Recovery at

A

B

C

D

E

F

G

H

K

Approx.

50°C Rise*

Floor to

Jacket

Vent

Floor to

Floor to

Floor to

Floor to

Floor to

Depth

Shipping

Number

Flue

Dia.

Size

T&P

Gas

Space

Space

Water

Weight

Nat.

Nat.

Conn.

Conn.

Conn.

Heating

Heating

Conn.

Liters

kW

Liters/

Return

Outlet

Input

Hour

mm.

mm.

mm.

mm.

mm.

mm.

mm.

mm.

mm.

kg.

U1-30S6FRN

114

8.8

117

1229

457

76x102

984

295

-

-

1187

565

50

U1-30T6FRN•

114

9.4

125

1502

406

76x102

1264 / 1432

295

-

-

1461

514

51

U1-403S6FRN•

151

11.7

155

1207

508

76x102

1041 / 1200

295

-

-

1232

615

62

U1-40T6FRN•

151

11.7

155

1508

457

76x102

1270 / 1438

295

-

-

1467

565

59

U1-404T6FRN•

151

14.7

201

1543

457

102

1308 / 1473

295

-

-

1486

565

62

U1-5036FRN•

189

11.7

155

1514

508

76x102

1270 / 1453

295

-

-

1473

615

70

U1-50L6FRN

182

11.7

155

1264

559

76x102

1029

295

-

-

1226

666

74

U1-504S6FRN•

189

14.7

201

1486

508

102

1270 / 1416

295

-

-

1448

615

73

U1-XR-403S6FRN

151

11.7

163

1270

508

76x102

1041

330

343

1041

1232

615

62

Available in Natural Gas only.

For 10 year models, change suffix from “6” to “10”. *Based on manufacturers rated recovery efficiency.

Note: U1-30S, U1-50L and U1-XR-403S do not have top T&P option.

•Models feature optional top T&P location and must be specified when ordering.

B

8'

All models meet SCAQMD rule 1121 requirement of 10ng/J,

K

or less, NOx emissions.

Meets NAECA Requirements

C

H

D&G

A

E

F

• Optional T&P Location Dimension “D” dimension listed as side/top.

General

All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All water connections are 3⁄4' NPT (19mm) on 8' (203mm) centers. All Gas Connections are 1/2' (13mm).

All models design certified by CSA International (formerly AGA/CGA), to meet ANSI standard Z-21.10.1 and peak performance rated.

Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.

Suitable for Water (Potable) Heating and Space Heating.

Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance.

Ambler, PA

Bradford White Water Heater Mi5036fbn Manual

For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.

Sales 800-523-2931 Fax 215-641-1670 / Technical Support 800-334-3393 Fax 269-795-1089 Warranty 800-531-2111 Fax 269-795-1089 International: Telephone 215-641-9400 Telefax 215-641-9750 / www.bradfordwhite.com

Bradford White Water Heater Mi40t6fbn Manual

Sales / Technical Support 866-690-0961 /905-238-0100 Fax 905-238-0105 /www.bradfordwhite.com

©2007, Bradford White Corporation. All rights reserved.

To continue the download you need to go through the captcha:

Bradford White Water Heater Brochure